>>>  I sent this last night but never got it in my own inbox, so I was wondering if it got lost or filtered.  
Sorry if you've gotten it already.
eugene
==============================================
It seems as though there might be a bit of a falloff in the WireChambers in the
left sector which might
correspond to the region of TOF 6-9.  I have 2 plots.  One is labeled
2004_efficiency.pdf   The other is
2005_inefficiency.pdf.  They are plots of the wire chambers.  They are 3D and
are somewhat close to
the geometry of the wire chambers (aside from a reflection through the BLAST x-y
axis). The window in
the 40-50 degree region in the WC is extremely obvious.  The runs used in this
analysis for 2005 are
14486-14493.  The runs used for 2004 are 11487-11493.  The height is the number
of hits in cells
that had tracks.  the x and y are 0-35 for the 35 cells and 0-5 for the 6
superlayers.
Again, I think we can conclusively say that the wire chambers show a hole... 
maybe because of TOF
inefficiency...  The right side is consistent in both years' datasets.
I've included one more postscript entitled 2004_left for a more obvious overhead
view of the 3D plot.
I hope these are understandable.
eugene
--------------------------------------------------------------------------
Eugene Geis
PhD Student, Physics Department, ASU
Research Affiliate, MIT-Bates Laboratory of Nuclear Science
eugene.geis@asu.edu
--------------------------------------------------------------------------
http://quickreaction.blogspot.com
----- End forwarded message -----
--------------------------------------------------------------------------
Eugene Geis
PhD Student, Physics Department, ASU
Research Affiliate, MIT-Bates Laboratory of Nuclear Science
eugene.geis@asu.edu
--------------------------------------------------------------------------
http://quickreaction.blogspot.com
This archive was generated by hypermail 2.1.2 : Mon Feb 24 2014 - 14:07:32 EST