Hi Tim,
   You are right about 'scalr' and 'inhib', and the 'p' or 'm' refers  
to the beam helicity.  The matrix was designed by Chi to accommodate  
mixtures of up to two spin states from the ABS, thus something like  
m_0j  is the charge on pure state 'j', and m_ij is the charge on  
combined states 'i,j', for the 6 deuterium states.  You can look  
through 'blast/exp/analysis/o/init.C' to see how the charges are  
added up.
--Chris
On Jan 20, 2006, at 10:59:17, Timothy Paul Smith wrote:
>
> Hello Blast_anaware,
>
> I am trying to understand the charge
> matrix in the DST.  I see four 7x7 matrix (scalr_charge_p,
> scalr_charge_m, inhib_charge_p, inhib_charge_m).
>
> What do their and there elements mean?  I've searched the
> website as best I can but have not found an explaintion.
>
> I am guessing that "scalr" is all current, "inhib" is when
> we are data taking? Which element goes with which state
> of the target?
>
> Tim
>
> -- 
>
> _____________________________________________________________
> Timothy Paul Smith                Assistant Research Professor
> Dartmouth College, Physics                       (603)646-9346
> 6127 Wilder, Hanover, NH 03755   timothy.p.smith@dartmouth.edu
> http://he3.dartmouth.edu/TimSmith
>
This archive was generated by hypermail 2.1.2 : Mon Feb 24 2014 - 14:07:33 EST